论著:主动呼吸控制放射治疗肺癌靶区位置误差分析
Analysis of Target Location Errors in Radiation Treatment of Non Small Cell Lung Cancer Using Active Breathing Control System
章娴 王健 朱姜轶 曾昭冲 吴铮 白春学
点击:1112次 下载:0次
作者单位:复旦大学附属中山医院放射治疗科
中文关键字:主动呼吸控制技术;非小细胞肺癌;放射疗法;分次治疗内误差;分次治疗间误差
英文关键字:Active breathing control;Non small cell lung cancer;Radiotherapy;Intra fractional radiotherapy error;Inter fractional radiotherapy error
中文摘要:目的:观察将主动呼吸控制(active breathing control,ABC)系统应用于非小细胞肺癌(non small cell lung cancer,NSCLC)的三维适形放射治疗(three dimensional conformal radiotherapy,3D-CRT)中所产生的靶区位置误差,分析其产生原因,探讨其在体部立体定向放射治疗(stereotacfic body radiotherapy,SBRT)中应用的可行性。方法:未行手术治疗的II~III期NSCLC患者8例,真空体模固定体位,模拟定位及放射治疗过程中全程应用ABC系统,3D-CRT治疗肺癌原发病灶。首次摆位时,在应用ABC系统状态下,每隔3 min以治疗体位在模拟机上拍摄定位片,连续拍摄5次,测定靶区位置误差模拟分次治疗内误差。治疗期间首周每天1次其后每周1次应用电子射野影像装置(electronic portal imaging device, EPID)拍摄验证片,测定靶区位置误差模拟分次治疗间误差。应用iviewGT系统分析分次治疗内及分次治疗间的误差。结果:8例患者分次治疗内误差: X轴(1.02±1.00)mm,Y轴(0.65±0.95)mm;分次治疗间误差:X轴(1.31±1.36)mm,Y轴(1.51±1.33)mm。结论:应用ABC系统后,3D CRT的分次治疗间及分次治疗的内误差较常规适形放射治疗显著缩小。
英文摘要:Objective:To analyze the comprehensive errors of the active breathing control (ABC) system and the causes when it is applied to three dimensional conformal radiotherapy(3D-CRT) for non small cell lung cancer(NSCLC) and to investigate the feasibility of its application in stereotactic body radiotherapy (SBR) for NSCLC. Methods:A total of 8 patients with phase II III NSCLC were fixed by the vacuum phantom and treated with 3D CRT. During the whole process of plan preparation and radiotherapy, ABC system was used to control the relative displacement caused by respiratory movement. Elekta iviewGT system was used to record the displacement of target position in the simulation and treatment. The inter fractional radiotherapy errors and the intra fractional radiotherapy errors were analyzed. Results: The overall inter fractional radiotherapy errors were (1.28±1.02) mm for the X axis positive direction and (1.07±1.76) mm for the Y axis positive direction. The overall intra fractional radiotherapy errors were (1.35±1.63) mm for the X axis positive direction and (1.38±1.50) mm for the Y axis positive direction. Conclusions: The inter fractional radiotherapy errors and intra fractional radiotherapy errors of 3D-CRT using ABC system were significantly smaller than those of conventional radiotherapy.
读者评论

      读者ID: 密码:   
我要评论:
主办单位:复旦大学附属中山医院
联系地址:上海市枫林路179号18号楼501室 邮编:200032
联系电话:021-60267570 E-Mail:(1)zglcyx@126.com; (2)zglcyxfb@126.com
版权所有©2009-2010 《中国临床医学》杂志编辑部 沪ICP备1103249号
本系统由北京菲斯特诺科技有限公司设计开发
您是本站第1269991名访问者